1. Multiple detection modules are optional, including PDA, UV/VIS, FL, RI and ELSD.
2. Built-in real-time solvent pressure compensation control improves detection accuracy; integrated check valve ensures stable fluid delivery and reduces daily maintenance workload.
3. Designed with low dead-volume flow path and high-pressure resistant structure. It delivers higher separation resolution, shorter analysis cycles and lower organic solvent consumption compared than standard HPLC systems.
4. High-frequency detector sampling ensures complete data collection of narrow chromatographic peaks, greatly enhancing sensitivity and reproducibility for trace impurity detection.

EX1800 ULBP Binary Ultra-High Pressure Linear Motor Infusion Module:
| Liquid Infusion System | Digital linear motor driven serial pump |
| Flow Rate Range | 0.001~5.000ml/min, 0.001ml/min increment |
| Max Output Pressure | 120MPa |
| Flow Accuracy | ≤0.06%RSD |
| Flow Precision | ≤±0.3% |
| Compression Compensation | Automatic, continuous, selectable solvent type |
| Post-column Cleaning | Automatic post-column cleaning function, which can control the cleaning flow rate |
| Gradient Setting Range | 0~100% |
| Extended Application | Record the number of times the plunger rod seal is used |
EX1800 SUV Detector:
| Flow Cell Volume | 1.0μl |
| Light Source | Deuterium lamp |
| Wavelength Range | 190~700nm |
| Spectrum Bandwidth | 4nm |
| Wavelength Accuracy | ±1nm |
| Wavelength Precision | 0.1nm |
| Noise | ≤0.2*10⁻⁵AU (Air cell, 254nm, 20°C) |
| Drift | ≤0.4*10-4AU/h (Air cell, 254nm, 20°C) |
| Sampling Frequency | 100Hz |

EX1800 PDA detector:
| Number of Diode Arrays | 512 |
| Light Source | Deuterium lamp + tungsten lamp |
| Wavelength Range | 200~800nm |
| Wavelength Precision | ±0.5nm |
| Wavelength Accuracy | ±0.1nm |
| Noise | ±5*10 -6AU, under specified conditions |
| Drift | 1*10-4AU/h, under specified conditions |
| Sampling Frequency | 100Hz |
| Spectral Bandwidth | 10nm |
Model | BK-1800UHPLC(Type I) Binary gradient automatic system with UV | BK-1800UHPLC(Type II) Binary gradient automatic system with PDA |
Diode Array Detector | / | Yes |
UV Detector | EX1800 SUV*1 | / |
Pump | EX1800 ULBP*1 | |
Solvent Manager | EX1800SO SD4*1 | |
Auto-sampler | EX1800 UAS*1, pressure resistant 120MPa, max 108pcs 2mL vials, quadruple protection device | |
Column Oven | EX1800 CO*1, temperature range: RT+5~80℃ | |
Pronaos EP-C18, 5μm, 4.6*250mm | Yes | |
Workstation EX-Clarity C50 | Yes | / |
Power Supply | AC220/110V, 50/60Hz | |
Optional Accessory | UV detector, RI detector, PDA detector, ELS detector, FL detector, column, EX1800 CO II refrigerated column oven: temperature range: RT-15~80℃ Auto-sampler: EX1800 UAS II, pressure resistant 120MPa, max 192pcs 2mL vials, quadruple protection device EX1800 UAS C II, pressure resistant 120MPa, max 192pcs 2mL vials, quadruple protection device, with cooling function | |
Package Size (W*D*H) | 720*580*410mm*4; 720*580*510mm | 720*580*410mm*4; 720*580*510mm |
Gross Weight | 32kg; 21kg; 18kg; 18kg; 33kg | 32kg; 23kg; 18kg; 18kg; 33kg |