Lorem ipsum dolor sit amet, consectetuer adipiscing elit, sed diam nonummy nibh euismod tincidunt ut laoreet dolore magna aliquam erat volutpat.
- Comfortable finger rest for both right and left hand usage
- Ideal shaft shape for reaching into narrow/deep tubes
- Each pipette calibrated as per ISO 8655-6 standards at our ISO 17025 accredited lab and supplied with individual calibration certificate
- Comes with an autoclavable lower assembly
- Attractive color coding for easy volume identification.
- Compatible with a wide range of tips
MULTICHANNEL PIPETTE
INCLUDES ALL BASICS FEATURES OF ACCUMAX VA-FA SINGLE CHANNEL & ADDITIONAL FEATURES LIKE
- Soft force & leak free tip loading and ejection.
- All internal components in the manifold are made of high-quality alloys produced by fine tooling to deliver precise volume across all channels
- Easily removable manifold for convenient maintenance
- 360° rotatable manifold for effortless and flexible pipetting
- One hand tip ejection.
- Attractive color coding for easy volume identification
- Compatible with most types of tips
PIPETTE STAND
VARIABLE VOLUME PIPETTES
Cat. No. | Volume Range [µl] | Increments [µl] | Test Volume [µl] | Inaccuracy (±) % | Inaccuracy (±) µl | Imprecision(±) % | Imprecision(±) µl |
---|---|---|---|---|---|---|---|
VA-100
|
0.5-10 µl
|
0.1
|
1
|
2.5
|
0.03
|
1.5
|
0.02
|
5
|
2
|
0.10
|
1
|
0.05
|
|||
10
|
1
|
0.10
|
0.8
|
0.08
|
|||
VA-125
|
0.1 – 2.5 µl
|
0.01
|
0.25
|
12
|
0.03
|
6
|
0.02
|
1.25
|
3
|
0.04
|
3
|
0.04
|
|||
2.5
|
2.5
|
0.06
|
1.6
|
0.04
|
|||
VA-200
|
5-50 µl
|
0.5
|
5
|
2
|
0.10
|
2
|
0.10
|
25
|
0.8
|
0.20
|
0.4
|
0.10
|
|||
50
|
0.6
|
0.3
|
0.3
|
0.15
|
|||
VA-300
|
50-200 µl
|
1
|
50
|
1
|
0.50
|
0.4
|
0.20
|
100
|
0.8
|
0.80
|
0.2
|
0.20
|
|||
200
|
0.60
|
1.20
|
0.15
|
0.30
|
|||
VA-400
|
200-1000 µl
|
5
|
200
|
0.9
|
1.80
|
0.3
|
0.6
|
500
|
0.75
|
3.75
|
0.25
|
1.25
|
|||
1000
|
0.60
|
6.00
|
0.2
|
2.00
|
|||
VA-500
|
10-100 µl
|
0.5
|
10
|
3
|
0.30
|
1.5
|
0.15
|
50
|
1
|
0.5
|
0.5
|
0.25
|
|||
100
|
0.8
|
0.80
|
0.15
|
0.15
|
|||
VA-600
|
100-1000 µl
|
5
|
100
|
2
|
2.00
|
0.7
|
0.70
|
500
|
1
|
5.00
|
0.4
|
2.00
|
|||
1000
|
0.6
|
6.00
|
0.2
|
2.00
|
|||
VA-700
|
2-20 µl
|
0.1
|
2
|
3
|
0.06
|
2
|
0.04
|
10
|
1.5
|
0.15
|
1
|
0.10
|
|||
20
|
0.9
|
0.18
|
0.4
|
0.08
|
|||
VA-800
|
20-200 µl
|
1
|
20
|
2
|
0.4
|
0.8
|
0.16
|
100
|
0.7
|
0.70
|
0.3
|
0.30
|
|||
200
|
0.6
|
1.20
|
0.15
|
0.30
|
|||
VA-900
|
1000-5000 µl
|
50
|
1000
|
0.8
|
8.00
|
0.3
|
3.00
|
2500
|
0.6
|
15.00
|
0.2
|
5.00
|
|||
5000
|
0.5
|
25.00
|
0.15
|
7.50
|
|||
VA-905
|
500-5000 µl
|
50
|
500
|
2
|
10.00
|
0.6
|
3.00
|
2500
|
0.6
|
15.00
|
0.3
|
7.50
|
|||
5000
|
0.5
|
25.00
|
0.15
|
7.50
|
|||
VA-1000
|
1000-10000 µl
|
100
|
1000
|
3
|
30.00
|
0.6
|
6.00
|
5000
|
1.2
|
60.00
|
0.30
|
15.00
|
|||
10000
|
0.60
|
60.00
|
0.2
|
20.00
|
|||
VA-1005
|
500-10000 µl
|
100
|
1000
|
3
|
30.00
|
0.6
|
6.00
|
5000
|
1.2
|
60.00
|
0.30
|
15.00
|
|||
10000
|
0.60
|
60.00
|
0.2
|
20.00
|
FIX VOLUME PIPETTES
Cat. No. | Volume Range [µl] | Test Volume [µl] | Inaccuracy (±) % | Inaccuracy (±) µl % | Imprecision(±) % | Imprecision(±) µl% |
---|---|---|---|---|---|---|
FA-205
|
2.5 µl
|
2.5
|
2
|
0.05
|
1.6
|
0.04
|
FA-5
|
5 µl
|
5
|
1.3
|
0.07
|
1.2
|
0.06
|
FA-10
|
10 µl
|
10
|
0.8
|
0.08
|
0.8
|
0.08
|
FA-20
|
20 µl
|
20
|
0.6
|
0.12
|
0.5
|
0.10
|
FA-25
|
25 µl
|
25
|
0.5
|
0.13
|
0.3
|
0.08
|
FA-50
|
50 µl
|
50
|
0.5
|
0.25
|
0.3
|
0.15
|
FA-100
|
100 µl
|
100
|
0.5
|
0.50
|
0.3
|
0.30
|
FA-200
|
200 µl
|
200
|
0.4
|
0.80
|
0.2
|
0.40
|
FA-250
|
250 µl
|
250
|
0.4
|
1.00
|
0.2
|
0.50
|
FA-500
|
500 µl
|
500
|
0.3
|
1.50
|
0.2
|
1.00
|
FA-1000
|
1000 µl
|
1000
|
0.3
|
3.00
|
0.2
|
2.00
|
FA-2000
|
2000 µl
|
2000
|
0.3
|
6.00
|
0.15
|
0.03
|
FA-5000
|
5000 µl
|
5000
|
0.3
|
15.00
|
0.15
|
7.50
|
FA-10000
|
10000 µl
|
10000
|
0.6
|
60.00
|
0.2
|
0.20
|
ACCUMAX VA-FA (MULTI 8 CHANNEL)
Cat. No. | Volume Range [µl] | Increments [µl] | Test Volume [µl] | Inaccuracy (±) % | Inaccuracy (±) µl % | Imprecision(±) % | Imprecision(±) µl% |
---|---|---|---|---|---|---|---|
MA8-010
|
0.5-10 µl
|
0.1
|
10
|
1.5
|
0.15
|
1.5
|
0.15
|
5
|
2.5
|
0.13
|
2.5
|
0.13
|
|||
1
|
4
|
0.04
|
4
|
0.04
|
|||
MA8-050
|
5-50 µl
|
0.5
|
50
|
1
|
0.50
|
0.7
|
0.35
|
25
|
1.5
|
0.38
|
1
|
0.25
|
|||
5
|
3
|
0.15
|
2
|
0.10
|
|||
MA8-100
|
10 – 100 µl
|
0.5
|
100
|
1
|
1.00
|
0.5
|
0.50
|
50
|
1
|
0.50
|
0.5
|
0.25
|
|||
10
|
1.5
|
0.15
|
0.75
|
0.08
|
|||
MA8-200
|
20-200 µl
|
1
|
200
|
0.7
|
1.40
|
0.25
|
0.50
|
100
|
1
|
1.00
|
0.4
|
0.40
|
|||
20
|
1.5
|
0.30
|
0.75
|
0.15
|
|||
MA8-300
|
30-300 µl
|
1
|
300
|
0.8
|
2.40
|
0.25
|
0.75
|
150
|
1
|
1.50
|
0.5
|
0.75
|
|||
30
|
1.5
|
0.45
|
0.75
|
0.23
|
ACCUMAX VA-FA (MULTI 12 CHANNEL)
Cat. No. | Volume Range [µl] | Increments [µl] | Test Volume [µl] | Inaccuracy (±) % | Inaccuracy (±) µl % | Imprecision(±) % | Imprecision(±) µl% |
---|---|---|---|---|---|---|---|
MA12-010
|
0.5-10 µl
|
0.1
|
10
|
1.5
|
0.15
|
1.5
|
0.15
|
5
|
2.5
|
0.13
|
2.5
|
0.13
|
|||
1
|
4
|
0.04
|
4
|
0.04
|
|||
MA12-050
|
5-50 µl
|
0.5
|
50
|
1
|
0.50
|
0.7
|
0.35
|
25
|
1.5
|
0.38
|
1
|
0.25
|
|||
5
|
3
|
0.15
|
2
|
0.10
|
|||
MA12-100
|
10 – 100 µl
|
0.5
|
100
|
1
|
1.00
|
0.5
|
0.50
|
50
|
1
|
0.50
|
0.5
|
0.25
|
|||
10
|
1.5
|
0.15
|
0.75
|
0.08
|
|||
MA12-200
|
20-200 µl
|
1
|
200
|
0.7
|
1.40
|
0.25
|
0.50
|
100
|
1
|
1.00
|
0.4
|
0.40
|
|||
20
|
1.5
|
0.30
|
0.75
|
0.15
|
|||
MA12-300
|
30-300 µl
|
1
|
300
|
0.8
|
2.40
|
0.25
|
0.75
|
150
|
1
|
1.50
|
0.5
|
0.75
|
|||
30
|
1.5
|
0.45
|
0.75
|
0.23
|
*10ml pipette doesn’t have tip ejector